Validation of Friedewald, Martin-Hopkins and Sampson low-density lipoprotein cholesterol equations

dc.authorid0000-0001-8738-0760tr
dc.authorid0000-0001-8738-0760tr
dc.contributor.authorGözde Ertürk Zararsız
dc.contributor.authorSerkan Bolat
dc.contributor.authorAhu Cephe
dc.contributor.authorNecla Kochan
dc.contributor.authorSerra İlayda Yerlitaş
dc.contributor.authorHalef Okan Doğan
dc.contributor.authorGökmen Zararsız
dc.date.accessioned2023-04-05T06:33:19Z
dc.date.available2023-04-05T06:33:19Z
dc.date.issued2022/5/13tr
dc.departmentTıp Fakültesitr
dc.description.abstractBackground: Low-density lipoprotein cholesterol (LDL-C) is an important biomarker for determining cardiovascular risk and regulating lipid lowering therapy. Therefore, the accurate estimation of LDL-C concentration is essential in cardiovascular disease diagnosis and prognosis. Sampson recently proposed a new formula for the estimation of LDL-C. However, little is known regarding the validation of this formula. Objectives: This study aimed to validate this new formula with other well-known formulas in Turkish population, composed of adults. Methods: A total of 88,943 participants above 18 years old at Sivas Cumhuriyet University Hospital (Sivas, Turkey) were included to this study. LDL-C was directly measured by homogeneous assays, i.e., Roche, Beckman and Siemens and estimated by Friedewald's, Martin-Hopkins', extended Martin-Hopkins' and Sampson's formulas. The concordances between the estimations obtained by the formulas and the direct measurements were evaluated both in general and separately for the LDL-C, TG and non-HDL-C sublevels. Linear regression analysis was applied and residual error plots were generated between each estimation and direct measurement method. Coefficient of determination (R2) and mean absolute deviations were also calculated. Results: The results showed that the extended Martin-Hopkins approach provided the most concordant results with the direct assays for LDL-C estimation. The results also showed that the highest concordances were obtained between the direct assays with the extended Martin-Hopkins formula calculated with the median statistics obtained from our own population. On the other hand, it was observed that the results of the methods may differ in different assays. The extended Martin-Hopkins approach, calculated from the median statistics of our population, gave the most concordant results in patients with "low LDL-C level (LDL-C levels < 70 mg/dL) or hypertriglyceridemia (TG levels ≥ 400 mg/dL)". Conclusions: Although the results of the formulas in different assays may vary, the extended Martin-Hopkins approach was the best one with the highest overall concordances. The validity of the Martin Hopkins' and Sampson's formulas has to be further investigated in different populations.tr
dc.identifier.doi10.1371/journal.pone.0263860en_US
dc.identifier.pmid35559957en_US
dc.identifier.scopus2-s2.0-85130045281en_US
dc.identifier.scopusqualityN/A
dc.identifier.urihttps://hdl.handle.net/20.500.12418/13334
dc.identifier.wosWOS:000835326900023en_US
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıtr
dc.rightsinfo:eu-repo/semantics/openAccesstr
dc.titleValidation of Friedewald, Martin-Hopkins and Sampson low-density lipoprotein cholesterol equationsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
journal.pone.0263860.pdf
Boyut:
3.44 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: