The effects of rectangular baffle angles and heights on heat transfer and pressure drop performance in cross-triangular grooved rectangular flow ducts

dc.authorid0000-0001-5680-0988tr
dc.contributor.authorKarabulut, Koray
dc.date.accessioned2024-05-30T08:44:51Z
dc.date.available2024-05-30T08:44:51Z
dc.date.issuedFEB 2024tr
dc.departmentSivas Meslek Yüksekokulutr
dc.description.abstractThe improvements in heat exchangers mainly focus on rising energy efficiency. The cross-grooved rectangular flow ducts are largely used for plate heat exchangers. In this study, to enhance the heat transfer and hydraulic-thermal performance in the cross-grooved rectangular ducts with triangular grooves, rectangular baffles were located in the duct, and the influences of the rectangular baffle angles and heights on the features of the heat transfer and pressure drop were numerically analyzed in detail. The equations of Navier-Stokes and energy were solved by employing the Ansys-Fluent program with the k-ε turbulence model as steady and three-dimensional. Air used as working fluid has an inlet temperature of 293 K while the triangular groove’s wall temperature is 373 K. Rectangular baffles have various angles of 30°, 60°, and 90°, and heights of 0.25H, 0.5H, and 0.75H. The mean Nusselt number (Num), dimensionless temperature (T*), turbulence kinetic energy (TKE*), pressure (p*), and performance evaluation criterion (PEC) number of the ducts with rectangular baffles were evaluated by comparing with the cross-triangular grooved duct without baffle. Also, the contours of turbulence kinetic energy, temperature, and velocity vector were exhibited for the cross-triangular grooved rectangular ducts with different arrangements of baffle angles and heights. Results were matched with experimental and computational outcomes of the study found in the literature, and it was observed that they were fairly compatible. The increment rate of Num at 90° baffle angle and 0.75H height is 197.56 % higher for Re = 6000 compared to 0.25H. Besides, for Re = 1000, the PEC number is 84.50 % higher at 0.25H baffle height and 30° angle than at 90°.tr
dc.identifier.doi10.1016/j.ijheatfluidflow.2023.109260en_US
dc.identifier.endpage15tr
dc.identifier.issue109260tr
dc.identifier.scopus2-s2.0-85182231005en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage1tr
dc.identifier.urihttps://hdl.handle.net/20.500.12418/15238
dc.identifier.volume105tr
dc.identifier.wosWOS:001134455900001en_US
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherElseviertr
dc.relation.ispartofInternational Journal of Heat and Fluid Flowen_US
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıtr
dc.rightsinfo:eu-repo/semantics/openAccesstr
dc.subjectCross-grooved duct, Rectangular baffle, Triangular groove, Plate heat exchangertr
dc.titleThe effects of rectangular baffle angles and heights on heat transfer and pressure drop performance in cross-triangular grooved rectangular flow ductsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Abstract-.pdf
Boyut:
112.95 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Kanıtlayıcı Belge
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: