Comparative Evaluation of the Effect of Different Rotary Instrument Systems on the Amount of Apically Extruded Debris

dc.contributor.authorÜnal, Bilge
dc.contributor.authorZan, Recai
dc.date.accessioned2024-10-26T17:51:24Z
dc.date.available2024-10-26T17:51:24Z
dc.date.issued2022
dc.departmentSivas Cumhuriyet Üniversitesi
dc.description.abstractObjectives: The purpose of our study is to examine in vitro the amount of debris extrusion from the apical after root canal preparation with different rotary instruments. Materials and Methods: In the present study, 60 single roots single-canal lower premolar human teeth were used. The teeth were randomly selected and divided into 4 main groups (n=15). Root canals are shaped by using 2Shape, One Curve, and XP-3DEndo Shaper working in rotational motion and WaveOne Gold working in reciprocal motion. Later, the weight of each eppendorf tube was weighed on a precision scale and the amount of debris extrusion from the apical was determined with 10?4 precision by subtracting the empty weight of the tube. Since the parametric test assumptions were fulfilled in the evaluation of the data obtained regarding the amount of debris extrusion from the apical of file systems by loading them into the SPSS 22.0 program, One-Way Variance analysis was used and the level of error was taken as 0.05. Results: When the amount of debris extrusion from the apical is ordered from high to low, it was seen that there are 2Shape, One Curve, XP-Endo Shaper, and WaveOne Gold. However, the difference between study groups was not statistically significant. Conclusions: Considering the results obtained in terms of debris extrusion from the apical about the new generation files with different metallurgy, kinematics, structural features, designs, and different configurations that we used in the present study, it was seen that these systems would not show any difference in terms of the effect of debris on the success of endodontic treatment © This work is licensed under Creative Commons Attribution 4.0 International License
dc.description.sponsorshipScientific Research Project Fund of Sivas Cumhuriyet University, (DİŞ-249)
dc.identifier.doi10.7126/cumudj.1128769
dc.identifier.endpage178
dc.identifier.issn2146-2852
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85133406264
dc.identifier.scopusqualityQ4
dc.identifier.startpage172
dc.identifier.trdizinid1129612
dc.identifier.urihttps://doi.org/10.7126/cumudj.1128769
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1129612
dc.identifier.urihttps://hdl.handle.net/20.500.12418/26188
dc.identifier.volume25
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherCumhuriyet University Faculty of Dentistry
dc.relation.ispartofCumhuriyet Dental Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectDebris extrusion; Endodontic treatment; Endodontics; Root canal treatment; Rotary systems
dc.titleComparative Evaluation of the Effect of Different Rotary Instrument Systems on the Amount of Apically Extruded Debris
dc.title.alternativeHastabaşı CAD-CAM Blokların Eroze Dentine Makaslama Bağlanma Dayanımı
dc.typeArticle

Dosyalar