Experimental exergy analysis of low-GWP R290 refrigerant and derivation of exergetic performance equations with regression algorithms

dc.authorid0000-0002-8356-181Xtr
dc.authorid0000-0002-4143-9226tr
dc.authorid0000-0003-3951-6138tr
dc.contributor.authorPektezel, Oğuzhan
dc.contributor.authorDaş, Mehmet
dc.contributor.authorAcar, Halil İbrahim
dc.date.accessioned2024-03-08T05:59:40Z
dc.date.available2024-03-08T05:59:40Z
dc.date.issued2023tr
dc.departmentMühendislik Fakültesitr
dc.description.abstractThis study analyses the derivation of performance equations for a refrigeration system operating with R290 and R404A refrigerants using different regression models. Results of pace regression for coefficient of performance (COP), second law efficiency, and total exergy destruction showed mean absolute error (MAE) are 0.0993, 0.0159, and 0.0066, respectively. In all cases, the pace regression model made better predictions than elastic net regression. It was concluded that predictions made with regression models showed a good agreement with the actual experimental results. The derived equations can be utilised for refrigerants working in similar operational ranges.tr
dc.identifier.citationPektezel, O., Daş, M., Acar, H. İ. (2023). Experimental exergy analysis of Low-GWP R290 refrigerant and derivation of exergetic performance equations with regression algorithms. International Journal of Exergy, 40(4), 467–482.tr
dc.identifier.doi10.1504/ijex.2023.130371en_US
dc.identifier.endpage482tr
dc.identifier.issue4tr
dc.identifier.scopus2-s2.0-85162052908en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage467tr
dc.identifier.urihttps://hdl.handle.net/20.500.12418/15002
dc.identifier.volume40tr
dc.identifier.wosWOS:000975574000006en_US
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.relation.ispartofInternational Journal of Exergyen_US
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıtr
dc.rightsinfo:eu-repo/semantics/openAccesstr
dc.titleExperimental exergy analysis of low-GWP R290 refrigerant and derivation of exergetic performance equations with regression algorithmsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
IJEX400406 PEKTEZEL_35238 (1).pdf
Boyut:
365.54 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: