Effect of Blood Donation Mediated Volume Reduction on Right Ventricular Function Parameters in Healthy Subjects

dc.contributor.authorKucukdurmaz, Zekeriya
dc.contributor.authorKarapinar, Hekim
dc.contributor.authorKaravelioglu, Yusuf
dc.contributor.authorAcar, Goksel
dc.contributor.authorGul, Ibrahim
dc.contributor.authorEmiroglu, Mehmet Yunus
dc.contributor.authorBulut, Mustafa
dc.contributor.authorEsen, Ali Metin
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:03:55Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:03:55Z
dc.date.issued2012
dc.department[Kucukdurmaz, Zekeriya -- Karapinar, Hekim -- Gul, Ibrahim] Cumhuriyet Univ, Dept Cardiol, Sch Med, Sivas, Turkey -- [Karapinar, Hekim -- Karavelioglu, Yusuf -- Acar, Goksel -- Emiroglu, Mehmet Yunus -- Bulut, Mustafa -- Esen, Ali Metin] Kartal Kosuyolu High Specialty Educ & Res Hosp, Dept Cardiol, Istanbul, Turkeyen_US
dc.description.abstractPurpose: We aimed to investigate the effect of controlled and limited volume change by the blood donation model to the right ventricular (RV) function via different echocardiographic parameters in healthy adults. Methods: Study population was composed of 71 healthy subjects who were volunteers for blood donation and evaluated before and after 450 mL blood donation. Pulsed-wave Doppler of the RV inflow and tissue Doppler of tricuspid lateral annulus, and tricuspid annular plane systolic excursion (TAPSE) were assessed. Results: E velocity of inflow decreased significantly (67.6 +/- 15.9 vs 60.9 +/- 12.2, P = 0.006). S and A velocities did not change (15.3 +/- 3.2 vs 15.2 +/- 2.5 cm/s, P = NS; 14.1 +/- 3.3 vs 13.4 +/- 3.1 cm/s, P = NS, respectively) but E showed significant decrease (13.7 +/- 2.9 vs 12.2 +/- 3.2 cm/s, P = 0.011). E/A ratio and E/E ratio were found to be unchanged (1.0 +/- 0.3 vs 1.0 +/- 0.4, P = NS; 5.1 +/- 2 vs 5.3 +/- 2, P = NS, respectively). Myocardial performance index (MPI) was found to be increased but ejection time obtained from the tricuspid annulus did not change (0.50 +/- 0.13 vs 0.54 +/- 0.11, P = 0.040; 243 +/- 37 vs 240 +/- 27, P = NS, respectively). Isovolumetric relaxation and contraction times showed difference close to the significance limit (56 +/- 19 vs 64 +/- 23 ms, P = 0.055; 61 +/- 16 vs 67 +/- 16 ms, P = 0.062, respectively). TAPSE decreased significantly (2.62 +/- 0.29 vs 2.41 +/- 0.27 mm, P = 0.005). Conclusion: E velocity and TAPSE were sensitive to a volume reduction as little as 450 mL in healthy subjects. MPI index of the tricuspid annulus is less sensitive than E and TAPSE but need much care under changing volume state. However S and A velocity and E/A ratio were found to be resistant to the effects of volume depletion. (Echocardiography 2012;29:451-454)en_US
dc.identifier.doi10.1111/j.1540-8175.2011.01614.xen_US
dc.identifier.endpage454en_US
dc.identifier.issn0742-2822
dc.identifier.issue4en_US
dc.identifier.pmid22324433en_US
dc.identifier.scopus2-s2.0-84859737055en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage451en_US
dc.identifier.urihttps://dx.doi.org/10.1111/j.1540-8175.2011.01614.x
dc.identifier.urihttps://hdl.handle.net/20.500.12418/9189
dc.identifier.volume29en_US
dc.identifier.wosWOS:000302540700020en_US
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWILEY-BLACKWELLen_US
dc.relation.ispartofECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUESen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectright hearten_US
dc.subjectsystolic functionen_US
dc.subjecttissue Doppleren_US
dc.subjectmyocardial performance indexen_US
dc.subjecttricuspid annular plane systolic excursionen_US
dc.titleEffect of Blood Donation Mediated Volume Reduction on Right Ventricular Function Parameters in Healthy Subjectsen_US
dc.typeArticleen_US

Dosyalar