An Experimental Approach for Understanding V-I Characteristic of Electric Arc Furnace Load

dc.contributor.authorSeker, Mustafa
dc.contributor.authorMemmedov, Arif
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:44:18Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:44:18Z
dc.date.issued2017
dc.department[Seker, Mustafa] Cumhuriyet Univ, Fac Engn, Dept Elect & Elect Engn, TR-58140 Sivas, Turkey -- [Memmedov, Arif] Inonu Univ, Fac Engn, Dept Elect & Elect Engn, TR-44280 Malatya, Turkeyen_US
dc.description.abstractElectric Arc Furnaces (EAF) are nonlinear loads causing power quality problems on the systems they are connected to. The main reason of EAFs causing power quality problems is the nonlinear characteristics of the electric arc. In this study, dynamic working characteristics of electric arc furnace load at Sivas Iron and Steel Incorporated Company (SIDEMIR) operating with 60 MVA EAF have been experimentally examined by HIOKI 3197 PQ analyser. Utilizing the measured dynamic load curves, mathematical equation and proper parameters have been determined for modelling electrical arc with the help of curve fitting methods on Matlab program. Also by modeling a phase equivalent of the system and harmonic filters existing on the system, a time domain model has been formed and with this model, harmonic effects of the EAF have been examined with Matlab/Simulink. Simulation results show that the presented model can be used for examining PQ and voltage harmonics problems caused by EAF loads.en_US
dc.description.sponsorshipInonu University Scientific Research Projects Department (IUBAP) [FDK-2011-135]en_US
dc.description.sponsorshipThis work was supported by Inonu University Scientific Research Projects Department (IUBAP). Project number: FDK-2011-135.en_US
dc.identifier.doi10.5755/j01.eie.23.3.18328en_US
dc.identifier.endpage35en_US
dc.identifier.issn1392-1215
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85020501825en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage30en_US
dc.identifier.urihttps://dx.doi.org/10.5755/j01.eie.23.3.18328
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7011
dc.identifier.volume23en_US
dc.identifier.wosWOS:000403903600005en_US
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherKAUNAS UNIV TECHNOLOGYen_US
dc.relation.ispartofELEKTRONIKA IR ELEKTROTECHNIKAen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectElectric arc furnaceen_US
dc.subjectV-I characteristicsen_US
dc.subjectcurve fittingen_US
dc.subjectharmonicsen_US
dc.titleAn Experimental Approach for Understanding V-I Characteristic of Electric Arc Furnace Loaden_US
dc.typeArticleen_US