Effect of Argon Plasma Pretreatment on Tensile Bond Strength of a Silicone Soft Liner to Denture Base Polymers

dc.contributor.authorBicer, Arzu Zeynep Yildirim
dc.contributor.authorDogan, Arife
dc.contributor.authorKeskin, Selda
dc.contributor.authorDogan, Orhan Murat
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:59:19Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:59:19Z
dc.date.issued2013
dc.department[Bicer, Arzu Zeynep Yildirim -- Dogan, Arife] Gazi Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey -- [Keskin, Selda] Penn State Univ, Dept Chem, University Pk, PA 16802 USA -- [Dogan, Orhan Murat] Cumhuriyet Univ, Dept Prosthodont, Sivas, Turkeyen_US
dc.description.abstractThis study evaluated the effect of argon plasma treatment on tensile bonding of heat-cured and auto-polymerized acrylic resins prior to the processing of a silicone soft liner. Both types of polymethylmethacrylate (PMMA) resins were treated with argon plasma for 1min or 10min (n=5). A control group, including untreated resin specimens, was also formed. After processing of the soft liner, the specimens were deflasked and stored dry for 24h, and they were then subjected to tensile bond strength testing. In order to see the plasma effect on the resin surface chemistry, representative specimens were analysed by XPS. Highest tensile bond strengths were observed in the 1-min exposure group for each resin, and 10-min exposure yielded the lowest bond strength likely due to the damaging effect of the plasma treatment. XPS analysis showed that the O/C ratios increased greatly in treated samples and that the binding energy values were not significantly changed.en_US
dc.identifier.doi10.1080/00218464.2013.768123en_US
dc.identifier.endpage610en_US
dc.identifier.issn0021-8464
dc.identifier.issn1545-5823
dc.identifier.issue7en_US
dc.identifier.scopus2-s2.0-84876130522en_US
dc.identifier.scopusqualityQ2
dc.identifier.startpage594en_US
dc.identifier.urihttps://dx.doi.org/10.1080/00218464.2013.768123
dc.identifier.urihttps://hdl.handle.net/20.500.12418/8636
dc.identifier.volume89en_US
dc.identifier.wosWOS:000316334300005en_US
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTAYLOR & FRANCIS LTDen_US
dc.relation.ispartofJOURNAL OF ADHESIONen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectArgon plasmaen_US
dc.subjectPMMAen_US
dc.subjectSilicone soft lineren_US
dc.subjectTensile bondingen_US
dc.subjectXPSen_US
dc.titleEffect of Argon Plasma Pretreatment on Tensile Bond Strength of a Silicone Soft Liner to Denture Base Polymersen_US
dc.typeArticleen_US

Dosyalar